Front Panel Features
  • Line activity LEDs
    • Printer output: sequential call#, date, time, digits dialed, tone/pulse dialing, call connect, disconnect and duration of call, number of rings, audio time and control condition, power on and down time, target case number and type of call.
    • 16 Button control keypad- Used to control unit operation & enter parameter setup program
    • Liquid crystal display- Indicates current status of lines or detailed information of a line. Also functions as a setup menu when altering the unit parameters.
    • Number of Lines

  • One standard-expandable to six
  • Memory Capacity
  • 1000 calls waited to be printed (optional)
  • Digit Capacity- sixty (60)
    Data Output-RS232 with multiple baud rates (optional)
  • Telephone Line Loading
    Bridging & Isolated from Ground-DC- 10 M ohm AC-200 K ohm (Idle line voltage 10 Vdc)
  • Decoder for Slave -852 Hz and 1633 Hz "C" tone
  • Rotary Dial
  • Dial pulse rate- 8 PPS to 22 PPS
  • Inter Digit time- 300 mS
  • Make/break ratio-50% to 80%
  • Touch Tone
  • Minimum duration-40 mS
  • Minimum inter digit time- 30 mS
  • Sensitivity- 25 dBm to -3 dBm
  • Ring Detector
  • Detects metallic ringing voltage (90 Vrms)
  • Line Activity- non blocking
  • Cassette Recorder Output
  • Separate audio output and relay contacts per line
  • Audio Output
  • Two line level outputs featuring Password protected audio with minimization per line
  • Distortion- -<5% over 300 to 4000 Hz
  • Alarms- Hold and decode at least 8 alarm numbers
  • Call counter-9999 Calls
  • Mean time Between Failure- Greater than 10,000 hours
  • Power Requirement- Standard 115 Vac +_10% 50/60 Hz, 70 watts
  • Size- 17.25"wide X 5.25" high X 12.75" deep
  • Weight- 25 lbs Max.